Webb23 mars 2013 · 4 Synthes Standard TPLO Jig and Saw Guides Technique Guide MCL 90º 3 mm–4 mm 2 Insert distal jig pin Instruments VW3001.15.10 Kirschner Wire 3.0 mm with trocar tip, length 150 mm, Stainless Steel 314.020 Screwdriver, hexagonal, small, with Holding Sleeve Place a 3.0 mm Kirschner wire jig pin through the distal jig pin hole on the … Webb241.132 3 50 mm 241.141 4 56 mm 241.152 5 67 mm 241.161 6 78 mm 241.172 7 89 mm 241.182 8 100 mm Synthes is a trademark of Synthes, Inc. or its affiliates. …

Orthopaedic Trauma DePuy Synthes - J&J MedTech

WebbThe Synthes Locking Compression Plates—T-Plates are intended to buttress metaphyseal fractures of the proximal humerus, medialtibial plateau and distal tibia. They are also for use in fixation of osteopenic bone and fixation of nonunions and malunions. The Synthes LCP Proximal Tibia Plate is intended for treatment of non-unions, malunions, WebbSynthes Mini Fragment Instrument and Implant Set with Self-Tapping Screws. Synthes Titanium Tibial Nail Accessory Implants. Synthes Locking Small Fragment LCP Instrument and Implant Set, with Self-Tapping … can issm be contractors https://funnyfantasylda.com

Synthes Small Fragment Instrument and Implant Set, …

http://www.gkqcw.com/admin/uppic/3.5%20mm%20LCP%20%20Distal%20Humerus%20Plates.pdf WebbSynthes has established the performance and safety of the Universal Small Frag-ment System, and that they represent state of the art medical devices for surgical treatment … WebbUsing a brush that is too big or too small for the diameter of the lumen/cannulation may not effectively clean the surface of a lumen/cannulation. After brushing ... Clean Synthes device ultrasonically for a minimum of 15 minutes, using a minimum frequency of 40 KHz . 10. Rinse device thoroughly with deionized (DI) or purified ... fivem all commands

Small Fragment Locking Compression Plate (LCP®) … Fragment …

Category:DePuy Synthes Small Fragment System Catalogue

Tags:Small fragment synthes

Small fragment synthes

SYNTHES LCP SURGICAL TECHNIQUE MANUAL Pdf Download

WebbPage 19 Selected Instruments from the Small Fragment LCP Instrument and Implant Sets Stainless Steel (105.434) and Titanium (145.434) continued 323.025 Direct Measuring Device 323.36 3.5 mm Universal Drill Guide 324.024 Push-Pull Reduction Device 324.031 Threaded Plate Holder, long, for 3.5 mm locking hole 329.04... WebbSmall Fragment Bending Instruments, in Modular Tray, Vario Case™ System which consists of: 68.122.019 Modular Tray for Small Fragment Bending Instruments, size 1/2, …

Small fragment synthes

Did you know?

http://synthes.vo.llnwd.net/o16/LLNWMB8/US%20Mobile/Synthes%20North%20America/Product%20Support%20Materials/Technique%20Guides/DSUSTRM10161165%20Rev%20C.pdf WebbThe Universal Small Fragment System is a streamlined system of instruments, coupled with standard and anatomic implants to support small fragment procedures. The …

WebbMultiple sizes and styles available for Synthes Small Fragment Instrument and Implant Set, With Self-Tapping Screws (105.408). CLICK HERE for list of mini fragment plates. … WebbSynthes Small Fragment LCP System that merges locking screw technology with conventional plating techniques. The combi-holes in the LCP limited-contact plate shaft combine a dynamic compression unit (DCU) hole with a locking screw hole. The head of the plate features four locking holes that accept locking screws B 3.5 mm, cortex screws

WebbLCP Small Fragment Set Page 3. f399.340 Bone Lever, malleable, width 10 mm, length 230 mm 1. 399.360 Periosteal Elevator, slightly curved blade, round edge, width 6 mm, length 190/90 mm 1. 399.400 Periosteal Elevator, slightly curved blade, straight edge, width 6 mm, length 187/87 mm 1. WebbThe Synthes Locking Compression Plates—Narrow and Broad, are intended for fixation of various long bones, such as the humerus, femur and tibia. They are also for use in …

WebbSmall Fragment Locking Compression Plate (LCP) System Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale in …

WebbInsert the screw using the Small Hexagonal Screwdriver [314.02]* for manual insertion or the Hexagonal Screw-driver Shaft [314.03]* with a power drive or a handle. Do not tighten the screw. 1 Insert a 3.5 mm Cortex Screw through the DCU portion of the elongated Combi hole. *Available in the Small Fragment LCP® Instrument and Implant Set fivem all car name list downloadhttp://synthes.vo.llnwd.net/o16/LLNWMB8/US%20Mobile/Synthes%20North%20America/Product%20Support%20Materials/Technique%20Guides/DSUSTRM09161080%20Rev%20B.pdf five make you fall in love with meWebbSynthes Small Fragment Locking Compression Plates (LCP) are intended for fixation of fractures, osteotomies and nonunions of the clavicle, scapula, olecranon, humerus, … canis symposia loginWebbFrom a conceptional viewpoint, the new Universal Small Fragment (USF) System was designed to perform more procedures with less equipment. This is markedly influenced by how the system is provided to the surgeon depending on the intended procedure. The USF System consists of two components: 1) Core Set and 2) Modular Anatomic Implant Trays. can i ssh from iphoneWebbAbout Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright ... fivem all objectsWebbThe Universal Small Fragment System consists of two components: 1) A core set of instruments, screws, and standard implants; and 2) modular anatomic implant trays for the supported small fragment anatomy. In addition, the core set can support all 2.7 mm/3.5 ®mm DePuy Synthes non-locking, LCP ®, and VA LCP plating technologies. fivem allowlistedhttp://synthes.vo.llnwd.net/o16/LLNWMB8/US%20Mobile/Synthes%20North%20America/Product%20Support%20Materials/Technique%20Guides/DSUSTRM10161165%20Rev%20C.pdf fivem allhousing